Filters: Coolant Filters
You are here: Home | Filters
| Coolant Filters

CSID
SERIES of Coolant Filters
|
The Magnetool CSID Series Coolant Filter utilizes the indexing
drum method of filtration, and is used with water based
coolant.
With Coolant Filter switch "ON", the Magnetic
drum remains in a static position. Dirty coolant is fed
from the machine into the reservoir of the Coolant Filter
and flows under the drum which attracts the ferrous particles
and builds up a "cake" of ferrous material. When
the coolant passageway is blocked the coolant rises until
it touches the probe. (The probe is the 1/4" diameter
stainless steel rod). This activates the motor turning the
drum a few degrees, clearing the passageway and allowing
the level of coolant to drop and the motor is turned off.
The swarf is eventually forced off the end of the discharge
chute.

CSO
SERIES of Coolant Filters
|
|
To check the operation of the drum, insert
the plug in a 115 Volt line, turn on the toggle
switch. Using a steel rod or screwdriver, short
the 1/4" dia. stainless steel probe to
the case. The drum will rotate while the probe
is shorted to the case.
The CSO Series is used when the coolant is
a non-conducting type of oil. The method of
magnetic separation is the same as the CSID.
However The drum and urethane squeegee roll
operate continuously. The oil is squeezed from
the swarf and flows back to the drum and eventually
to the tank. The swarf is forced off the end
of the discharge chute.
|
|
|
ORDERING INFORMATION
 |
CSO Series Coolant Filters
|
|
|
|
|
|
|
"C" &
"D" HEIGHT AND LENGTH
|
|
|
|
CSO/CSID -30
|
10
|
4-1/4
|
10
|
9-1/4 x 17
|
95
|
120V 60 Hz 1/20 HP
|
|
CSO/CSID -60
|
20
|
8-7/16
|
13-1/16
|
9-1/4 x 17
|
150
|
120V 60 Hz 1/20 HP
|
|
CSO/CSID -90
|
30
|
12-5/8
|
17-5/16
|
9-1/4 x 17
|
200
|
120V 60 Hz 1/20 HP
|
|
|
|

|